Operating Manual
15. Installation
The camera must be installed in an environmentally sealed enclosure that offers
protection from moisture or high humidity. It is also recommended that desiccant
be installed in the camera enclosure to absorb excess humidity. Failure to install or
replace the desiccant as required may cause malfunctions or damage the camera.
15.1 Enclosures
Refer to Appendix A for recommended enclosures.
15.2 Mounting Holes
For flexibility, the camera is equipped with 2 different sets of mounting holes
(Figure 13). There are three ¼-20 threaded mounting holes along the centre of the
camera that are spaced 2.0” (50.8mm) apart. The setscrews need to be removed
with a 1/8” hex Allen key to use the ¼-20 threaded mounting holes. At least two
of the ¼-20 threaded holes are required for mounting the camera. The camera is
also equipped with four #4-40 threaded mounting holes that are spaced 1.5” x 5.0”
(38 mm x 127 mm) apart.
Important: The fasteners used for mounting must be 0.375 inches (9.5 mm) or
shorter. Using longer fasteners can cause damage to the camera by protruding too
far into the camera and damaging the circuit boards. It is recommended to use
only the fasteners provided with the camera.
Figure 13 Mounting Holes
37