fi-5120C / fi-5220C Image Scanner Operator
Guide
TROUBLE SHOOTING
CONTENTS MAP
TOP
5.3 Replacing the Pick Roller (3)
1 2
3
4
7. Attach the Pick roller to the scanner.
Attatch the Pick roller to the scanner in reverse order of the procedure for removing.
1. Turn the Pick roller bushing in the direction indicated by the arrow.
Pick Roller Bushing
Pick Roller Shaft
2. Move the sheet guide claws in the direction indicated by the arrow to fix the sheet guide.
8. Press down the center of the ADF to return it to its original position.
You should hear the ADF click when it returns to its original position.
9. Attach the ADF paper chute.
With the movie below, review the replacement procedure of the Pick roller:
1 2
3
4
All Rights Reserved Copyright 2006-2009 © PFU LIMITED