6.3 Remedying Typical Troubles
Symptom: The scanned images are elongated
Back
Have you cleaned all the rollers?
NO
Clean all the rollers. (*)
YES
Have you adjusted the scan scale?
YES
Check the items in "6.4 Items to check before
contacting the dealer where you bought the
scanner" and contact the dealer or an
authorized FUJITSU scanner service provider.
NO
Set the scan scale.
Display the properties of the scanner that you
are
using on "Scanners and Cameras" in the
control
panel, then adjust the scan scale.
*) For details on how to clean the rollers, see "4.3 Cleaning the ADF".