7.4. Internal Switch and Jumper Settings
For VD and HD input/output and termination refer to “6.2. Input-output of HD/VD Signals.”
For alternative connections of pin #10 and #11 on 12-pin connector, jumper JP1, JP2, JP3, JP4
and JP5 can be used. Refer “5.3. Input and Output Circuits.”
Jumper setting for alternative pin configuration for M-series camera emulating is shown below.
Pin # Function JP2 JP3 JP5 JP1 JP4 Remarks
9 PCLK out Short Factory default setting (EIA-J standard)
9 No connection Open
10 WEN out Open Short Factory default setting (EIA-J standard)
10 Ground Short Open
11 Ext. trigger in Open Short Factory default setting (EIA-J standard)
11 +12 Volt in/out Short Open Warning! +12 volt power out here.
Fuse
Fig. 27. Jumper positions.
8. External Appearance and Dimensions
Fig. 28. Dimensions
- 20 -