JAI CV-A33CL Security Camera User Manual


 
CV-A33CL
- 11 -
6.2.4. LVAL a-synchronous accumulation
The CV-A33CL has LVAL a-synchronous accumulations only. The accumulation will start 28 µsec.
after the trigger leading edge. EEN will indicate the accumulation time. When the accumulation
stops after the selected shutter time, the LVAL phase is reset and restarted.
1 LVAL = 16.825 µsec.
16.8 µsec.
Trigger
Accum
LVAL
Delay 28 µsec.
EEN
16.8 µsec.
Trigger
Accum
LVAL
Delay 28 µsec.
EEN
Trigger
Accum
LVAL
Delay 28 µsec.
EEN
Fig. 16. LVAL a-synchronous accumulation
In CV-A33 with LVAL a-synchronous accumulation a new trigger can be input and start a new
exposure during the previous frame read out. But the exposure may not be finished before the
frame is read out. It makes it possible to have a trigger rate close to the frame rate.
The minimum trigger interval should be >(1FVAL + 1 LVAL).