JAI CV-A33CL Security Camera User Manual


 
CV-A33CL
- 18 -
6.5. Other Functions.
User ID.
The command (UD) the user can save up to 16 characters in the camera to identify the camera.
Bit Allocation.
The command (BA) will select the number of bits in the Camera Link output to 8 or 10 bit.
Black Level.
The command (BL) is for adjusting the video black level (or set-up level).
GAin level.
The command (GA) is for adjusting the gain level between 0 and 15 dB.
CaliBration of CMOS sensor.
This command (CB=0) will calibrate all the A/D converters on the CMOS sensor. The calibration
procedure for gain and offset is done automatically each time the command is received and at
power up. Allow the camera to warm up before the calibration is done.
The data from the calibration can be stored in a file by the camera control tool by the command
“Read Calibration” and “Write to File”. With the command “Read from File” the calibration data
can be loaded to the camera and used as calibration.
Important notes on using this function.
“Read Calibration” takes about 22 seconds.
“Read from File” takes about 45 seconds.
7. Configuring the Camera
7.1. Switch setting inside
SW 200 is for selecting the RS232C input through Camera Link or the 12 pin HR connector.
SW 200 is placed inside on the camera motherboard PK8387B near the rear.
SW 300 is for 75 terminating of the trigger input on pin #10 on 12 pin HR connector.
SW 300 is placed inside on the rear board PK8388B. (On for 75 terminating.)
SW 200
On Off
CL HR
SW 200
On Off
CL HR
SW 300
On
Off
Trig. Pin #10
1 2
SW 300
On
Off
Trig. Pin #10
1 2
Fig. 24. Internal switch setting