JAI CV-A33CL Security Camera User Manual


 
CV-A33CL
- 12 -
6.2.5. Timing for window of interest
With WS=1, the X and Y start coordinates (WX and WY), and the width and height (WW and WH)
for the window of interest can be programmed with 1 pixel interval. The minimum window size
is 2(h) x 3 (v). If the window is specified outside the full image area, it will be placed up to the
right or low limit as shown in fig 17. right.
Figures marked with (*) in the timing diagrams below will change with other window settings.
(0, 0)
(658, 492)
Active Pixel Array
659
493
120
240
(200, 100)
(0, 0)
(658, 492)
Active Pixel Array
659
493
100
100
(559, 393)
Readout Region
(WX=559, WY=393, WW=100, WH=100)
Specifyed Region
(WX=600, WY=400, WW=100, WH=100)
Fig. 17. Window of interest.
1 LVAL = 16.825
µ
s
L VAL
DA TA OUT
FVAL
Ef f ect i ve Li nes
2
1
6
2
1
5
……
120L( *)
125L( * )
129L( * )
……
1 FVAL per i od
2
1
7
2
1
9
2
1
8
DVAL
4L
……
5L 4L
1
0
0
1
0
1
1
0
2
1
0
3
1
0
4
1
0
0
1
0
1
1
0
2
1
0
3
1
0
4
(*) Variable Number
Fig. 18. Vertical timing for window of interest.
DA TA OUT
L VAL
Ef fecti ve Pi xel s
……
240ck(*)
668ck
673ck
1 LVAL per i od
DVAL
5ck
9ck
9ck
5ck
200ck(*)
4
3
7
4
3
8
4
3
9
2
0
0
2
0
1
2
0
2
……
219ck( *)
(*) Variable Number
1 ck = 25 nsec