–74–
Setting the Electronic Shutter
Changing the Shutter Speed/Mode Selection Range
The shutter speed selection range can be limited to the required range and whether to use a
special operation mode can be selected at the SHUTTER SPEED page of the setting menu. The
unit is set so that the SHUTTER SPEED page is not displayed when shipped from the factory.
To operate the SHUTTER SPEED page, switch the unit to engineer mode or select the SHUT-
TER SPEED page at the MENU SELECT page beforehand.
1 Set the MENU SET/OFF switch to SET.
The page on which the previous setting menu operations were completed appears on the
viewfinder screen. (When the menu is used for the first time, the first page appears.)
2 Press the PAGE button repeatedly until the SHUTTER SPEED page shown below appears.
(This operation can also be performed using the PAGEoUP/DOWN function.)
3 Press the SHIFT/ITEM button repeatedly to move the cursor to the position of the mode or
shutter speed to be set.
4 The selected mode or speed changes from used (ON) to not used (OFF) and vice versa
each time the UP (or DOWN) button is pressed.
5 When menu operations have been completed, set the MENU SET/OFF switch to OFF. The
setting menu disappears from the viewfinder screen and the displays indicating the unit’s
current status appear at the top and bottom of the viewfinder screen.
|Note{
When operating the unit from the AQ-EC1 extension control unit (option), even if the SHUTTER
SPEED page is operated from the unit, the switches of the AQ-EC1 have priority regarding the
actual shutter speed.
ÁSee “Setting Menu Configuration” (page 47) for a description of engineering mode and select-
ing display pages.
Changing the lris Automatic Adjustment Reference Value
To change the reference value, change the A. IRIS LEVEL, A. IRIS PEAK/AVE, A. IRIS MODE
value on the LEVEL 6/6 page of the setting menu using the UP or DOWN button.
|Note{
The ON/OFF status for each item is
indicated by displaying an asterix (E)
or period (
.
) in front of the item on the
screen.
-
SHUTTER SPEED
-
¢
ESYNCHR
O
SCAN
.
SUPER V
E1 /100
E1/ 120
E1/ 250
E1/ 500
E1/ 1000
E1/ 2000