When the server certificate has expired, the HTTPS function will become unavailable. When the
camera is restarted, the connection protocol will be changed to HTTP. Update the server certificate
before it expires.
The expiration date of the server certificate can be checked by double-clicking the server certification
file issued by CA.
17.2.5 Configuration of the connection protocol
1. Select “HTTP” or “HTTPS” for “Connection” to determine the protocol used to access the camera.
HTTP: Only the HTTP connection is available.
HTTPS: Only the HTTPS connection is available.
2. Designate the HTTPS port number to be used for “HTTPS port”.
Available port number: 1 - 65535
Default: 443
The following port numbers are unavailable since they are already in use.
20, 21, 23, 25, 42, 53, 67, 68, 69, 80, 110, 123, 161, 162, 554, 995, 10669, 10670, 59000 - 61000
3. Click the [Set] button.
The camera will restart, and it will become possible to access to the cameras using the HTTPS protocol.
(®page 9, page 18, page 20)
Note
The camera will restart after the connection setting is changed.
When using the self-signed certificate:
If the camera is accessed using the HTTPS protocol for the first time, the warning window will be
displayed. In this case, follow the instructions of the wizard to install the self-signed (security) certificate.
(®page 179)
When using the server certificate:
In advance, install the root certificate and intermediate certificate on the browser in use. Follow the
instructions of CA for how to obtain and install these certificates.
When the camera is accessed using the HTTPS protocol, the refresh interval and frame rate of images
may be lower.
When the camera is accessed using the HTTPS protocol, it may take time to display images.
When the camera is accessed using the HTTPS protocol, the images may be distorted or audio may
be interrupted.
When the camera is accessed using the HTTPS protocol, the number of users that can access the
camera may be reduced. The maximum number of concurrent access user varies depending on the
maximum image size and transmission format.
17.3 Access the camera using the HTTPS protocol
(SW355, SW352, SW316L, SW316, SW314, SW155,
SW152, SF135, SF132, SW115)
Note
WV-SW355R and WV-SW352R do not support the HTTPS function.
1. Start up the web browser.
2. Enter the IP address of the camera in the address box of the browser.
Example of entry: https://192.168.0.10/
178 Operating Instructions
17 Configuring the network settings [Network]