Paradyne 8820 Security Camera User Manual


 
8000-A2-GB30-10 November 2003 71
7.2.2 mpeEntPhysicalExtOperStatus
This is a read-only object that allows managers to determine the operational status of the
entities in the managed device. The possibles values are ’up’, ’down’ and ’testing’.
7.3 Entity Sensor MIB (RFC 3433):
This MIB has only one group (entitySensorValueGroup) which consists of a single
(read-only) table that will be supported as indicated in the following table. There will be as
many entries as sensors. For the GranDSLAM R3.2 product, there will be three temperature
sensors
7.3.1 entPhySensorType.
The value for this object corresponds to the measurement data type. The value of this object
will be celsius (8).
7.3.2 entPhySensorValue.
The value corresponds the most recent measurement obtained by the agent for this sensor.
7.3.3 entPhySensorOperStatus.
The operational status of the sensor. The following status will be reported: ok (1),
unavailable (2), nonoperational (3).
7.3.4 entPhySensorValueTimeStamp.
The value of this object corresponds to the sysUpTime at the time the status and/or value fo
this sensor was last obtained by the agent.
7.3.5 entPhySensorValueUpdateRate.
The value of this object is an indication of the frequency that the agent updates the
associated entPhySensorValue object. The value to be returned will be zero. This value has
a special meaning in the mib.
7.4 Definitions for the IEEE 802.3 Medium Attachment Units (MAUs) (RFC 2668):
RFC 2668 is used for accessing information about of ethernet interface. The following
objects are supported.
7.4.1 ifMauTable:
Table of descriptive and status information about MAU(s) attached to an interface. The
following objects in this table are supported.
Table 1-82. Entity Sensor MIB
Table Comments
entPhySensorEntry Only the objects listed below will be supported