NOTE:
Pattern length is set
on the secondary menu
entitled Other.
NOTE:
To make the pattern
run to its end when an alarm
activates it, make alarm
dwell time longer than
pattern length. Thus, if the
alarm goes away before the
end of the pattern, the
pattern will continue until the
dwell times out.
ALARMS
The Spectra II dome has seven alarm inputs, which can be designated as either high or low
priority. The high priority setting is significant when more than one alarm is activated. If priority in
alarms is not required, leave all alarms in the low setting. Refer to the
Alarm Priority
section.
If presets 1-7 are not used for alarms, they can be used as regular presets. However, if they
are being used for alarms, they should not be used for anything else.
Also refer to the
Alarm Dwell, Alarm Pattern, Alarm Resume,
and
Pattern Length
sections
to program alarm conditions.
ALARM DWELL
Main Menu
Alarms, Zone Blank Menu
<Camera>
<Line Sync>
<Power Up>
<Aux>
<Alarms, Zone Blank>
<Other>
EXIT
Alarm resume Off
Alarm dwell sec 5
<Alarm priority>
<Alarm pattern>
<Zone blank>
Exit
This is the minimum time the Spectra II will stay at an alarm even if the alarm is present for
less than this amount of time.
To change the alarm dwell:
1. Program preset 95 (28). The main menu appears.
2. Position the cursor (>) beside Alarms, Zone Blank.
3. Press the Iris Open button to enter the Alarms, Zone Blank menu.
4. Position the cursor (>) beside Alarm Dwell Sec.
5. Press the Iris Open button. The cursor moves to the right, beside the number of
seconds for the alarm dwell time.
6. Move the joystick up or down and hold to cycle through 1-200 seconds in one-second
increments.
7. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
ALARM PATTERN
Main Menu
Alarms, Zone Blank Menu
Alarm Pattern Menu
<Camera>
<Line Sync>
<Power Up>
<Aux>
<Alarms, Zone Blank>
<Other>
EXIT
Alarm 1No Pattern
2No Pattern
3No Pattern
4No Pattern
5No Pattern
6No Pattern
7No Pattern
Exit
Alarm resume Off
Alarm dwell sec 5
<Alarm priority>
<Alarm pattern>
<Zone blank>
Exit
You can choose one of the following for each of the seven alarm inputs:
Full Pat (run full pattern) Half Pat 2 (run half pattern 2)
Half Pat 1 (run half pattern 1) No Pattern
In response to an alarm, the Spectra II dome can do either one full pattern (1.5, 3, or 6
minutes long) or two half patterns (.75, 1.5, or 3 minutes long).
To change the alarm pattern:
1. Program preset 95 (28). The main menu appears.
2. Position the cursor (>) beside Alarms, Zone Blank.
3. Press the Iris Open button to enter the Alarms, Zone Blank menu.
4. Position the cursor (>) beside Alarm Pattern.
5. Press the Iris Open button to enter the Alarm Pattern menu.
Pelco Manual C2423M (5/00) 10