NOTE:
The Spectra II
Color/Black and White
camera cannot do electronic
zoom in a pattern. Optical
zoom will operate in a
pattern.
6. Position the cursor (>) beside the number of the alarm input for which you want to set
the pattern.
7. Press the Iris Open button. The cursor moves to the right, beside the words Full Pat,
Half Pat 1, Half Pat 2, or No Pattern.
8. Move the joystick up or down to toggle between the choices.
9. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
ALARM PRIORITY
Main Menu
<Camera>
<Line Sync>
<Power Up>
<Aux>
<Alarms, Zone Blank>
<Other>
EXIT
Alarms, Zone Blank Menu
Alarm Priority Menu
Alarm resume Off
Alarm dwell sec 5
<Alarm priority>
<Alarm pattern>
<Zone blank>
Exit
Alarm 1 Low
2 Low
3 Low
4 Low
5 Low
6 Low
7 Low
Exit
This feature lets you set alarm priority inputs as one of the following:
High - A high priority alarm will not release to a low priority alarm.
Low - Alarms will release or sequence between low priority alarms only if no high
priority alarm exists.
To change alarm priority:
1. Program preset 95 (28). The main menu appears.
2. Position the cursor (>) beside Alarms, Zone Blank.
3. Press the Iris Open button to enter the Alarms, Zone Blank menu.
4. Position the cursor (>) beside Alarm Priority.
5. Press the Iris Open button to enter the Alarm Priority menu.
6. Position the cursor (>) beside the number of the alarm input for which you want to set
the priority.
7. Press the Iris Open button. The cursor moves to the right, beside the word High or Low.
8. Move the joystick up or down to toggle between the words High and Low.
9. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
ALARM RESUME
Main Menu
<Camera>
<Line Sync>
<Power Up>
<Aux>
<Alarms, Zone Blank>
<Other>
EXIT
Alarms, Zone Blank Menu
Alarm resume Off
Alarm dwell sec 5
<Alarm priority>
<Alarm pattern>
<Zone blank>
Exit
This mode lets the dome resume its previous activity (scan, pattern, or previous position)
after all alarms are cleared.
There are two alarm resume modes:
On - Alarm resume mode is enabled.
Off - Alarm resume mode is disabled.
To change the alarm resume mode:
1. Program preset 95 (28). The main menu appears.
2. Position the cursor (>) beside Alarms, Zone Blank.
3. Press the Iris Open button to enter the Alarms, Zone Blank menu.
4. Position the cursor (>) beside Alarm Resume.
5. Press the Iris Open button. The cursor moves to the right, beside the word On or Off.
6. Move the joystick up or down to toggle between On or Off.
7. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
Pelco Manual C2423M (5/00) 11