C3403M-A (3/06) 23
PARK TIME
This feature allows the dome to begin preset 1 after a programmed time of inactivity.
Park time can be programmed from 1 minute to 720 minutes (12 hours), or it can be set to zero,
which disables this feature. The default setting is zero.
Park Action
This feature will define the activity when the dome parks. The following settings are available:
NONE (default) No action.
PRESET 1 Dome goes to preset 1.
SCAN SPEED
Scan speed is the degrees per second that the dome will pan when in a scan mode. Scan speed
is adjustable for 3, 6, or 12 degrees per second through the programming menu. The default
setting is 6 degrees per second.
(See page 9)
Quick Programming Guide
EXIT
PELCO SPECTRA MINI
LANGUAGE ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERN>
<ZONES>
<WINDOW BLANKING>
<CLEAR>
<PASSWORD>
BACK
EXIT
DOME SETTINGS
MOTION
AUTO FLIP ON
PROPORTIONAL PAN ON
PARK TIME (MINUTES) 0
PARK ACTION NONE
SCAN SPEED (DEG/S) 6
LIMIT STOPS ON
<SET MANUAL STOPS>
<CLEAR MANUAL STOPS>
<SET SCAN STOPS>
<CLEAR SCAN STOPS>
<SET AZIMUTH ZERO>
<CLEAR AZIMUTH ZERO>
BACK
EXIT
REFERENCE INFORMATION
MANUAL LIMITS SET NO
SCAN LIMITS SET NO