Sepuence Setting
Power On Resume : When the power supply for the camera is stopped for some
reason, such as electricity failure, and resumed, the Sequence
Settings before the power off are restored.
Pan Limit : The moving range in the Pan direction can be limited.
Preset
Swing SEQ
Group SEQ
Tour SEQ
PTZ Trace
Auto Run
Power On Resume OFF
Sepuence Setting
Preset
Swing SEQ
Group SEQ
Tour SEQ
PTZ Trace
Auto Run
Power On Resume ON
Main Menu
Camera Setting
Sequence Setting
P/T Setting
OSD Setting
Alarm Setting
Initialize
Status
P/T Setting
Pan Limit
Tilt Limit
Area Setting
Area Masking
Prop. P/T ON
Digital Flip ON
Image Hold OFF
Position : Moving range can be set up. Set the position from the left using the
joystick and the Execution key. The stop position may change due to the
initialization by such operation as power resumption depending on
position setting. This does not mean it is out of order.
On/Off : When this function is on, the limit is effective. Default setting is Off.
Tilt Limit : Moving range in the tilt direction can be limited.
Main Menu
Camera Setting
Sequence Setting
P/T Setting
OSD Setting
Alarm Setting
Initialize
Status
P/T Setting
Pan Limit
Tilt Limit
Area Setting
Area Masking
Prop. P/T ON
Digital Flip ON
Image Hold OFF
Position : Moving range can be set up. Set the position from the top direction
using the joystick and the Execution key. The stop position may change
due to initialization by such operation as power resumption depending
on position setting. This does not mean it is out of order.
On/Off : The application of limitation will be determined. Default setting is Off.
Replay : The manual operation paths are repeated and replayed. Stop key will stop the
replay.
* If the operation range is limited using Pan Limit and Tilt Limit, please note that other operations
beyond the limited operation range are not possible.
Memorize: Manual operations for minimum 120 seconds after executing this function are
memorized into the internal memory. Nevertheless, the memorizing time
becomes different depending on the PTZ operation. OVER mark will finish this
function.
* If the operation range is limited using Pan Limit and Tilt Limit, only the operations within the
limited range are memorized.
Auto Run: If there is no controller operation by the user for a certain time, the
sequence operation designated by the user will be executed.
Mode - • OFF : Auto Run will be cancelled.
• Preset : Auto Run in the corresponding Preset number
• Swing : Auto Run in the corresponding Swing mode
• Group : Auto Run in the corresponding Group number
• Tour : Auto Run in the corresponding Tour number
• Trace : Auto Run in the corresponding Trace number
• A. Pan : 360˚ Auto Run in Pan direction
* Auto Pan Speed: Pan operation in the speed designated by the user
* Tilt Angle: The tilt angle set up by the user is kept.
Time : Auto Run operation is executed after a certain time designated by the user.
*Time can be set up by the unit of 1-59 sec and 1-59 min.
Functional Description
3) P/T Setting