Title Display
The camera can be given a title containing up to 20
characters such as “ENTRANCE” or “LOBBY”. The
position of the first character (horizontal, vertical) of
the title, blinking state, and color can also be changed.
Vposition 00 to 0A
Hposition 00 to 17
Blink
00: Does not blink
01: Blinks
00 White
01 Yellow
02 Violet
Color 03 Red
04 Cyan
05 Green
06 Blue
00 01 02 03 04 05 06 07
AB CDEF GH
08 09 0a 0b 0c 0d 0e 0f
IJKLMNOP
10 11 12 13 14 15 16 17
QR STUVWX
18 19 1a 1b 1c 1d 1e 1f
YZ& ? ! 1 2
20 21 22 23 24 25 26 27
34567890
28 29 2a 2b 2c 2d 2e 2f
ÀÈ ÌÒÙÁ É Í
30 31 32 33 34 35 36 37
ÓÚÂÊÔÆŒÃ
38 39 3a 3b 3c 3d 3e 3f
ÕÑÇßÄÏ ÖÜ
40 41 42 43 44 45 46 47
Å$
F
¥D ¿ ¡
48 49 4a 4b 4c 4d 4e 4f
ø“ :‘ . , / -
Synchronization Methods
Internal and external synchronization are available;
VISCA Commands allow you to switch between them.
• Internal Synchronization
An internal vibrator inside the camera generates a
synchronizing signal as a basic oscillator.
NTSC=28.636363MHz
PAL=28.375MHz
External Synchronization (V-Lock Synchronization)
When a TTL level V-Lock pulse is input, the camera
synchronizes to the input signal (V-lock
synchronization). The frequency of the input signal
synchronizes to within ±1Hz of the external
synchronization.
Also, V-Phase phase adjustment can be carried out to
within ±90 degrees due to the V-Lock phase
adjustment. In addition, 360 degree phase adjustment
is possible because you can switch between 0 degree
and 180 degree phases.
Because V-Lock synchronization is a simple synchronization
method, color signals like a VBS “GenLock” cannot be
synchronized.