Sony Ericsson XCI-V3 Digital Camera User Manual


 
22
External Control Commands
External Control Commands
Overview
The XCI-SX1/V3 can be controlled externally from a
host device via a serial communication and telnet using
such communication softwares as “HyperTerminal” or
“Tera Term.”
Serial Communication
Specifications
The serial communication system for the XCI-SX1/V3
is an asynchronous method compliant with RS-232C.
The following table shows the transmission control
specifications.
Baud rate
115200/57600/38400/19200/9600/4800 [bps]
Default setting: 38400 [bps]
Data bits 8
Parity None
Stop bit 1
Flow control None
Authentication None
The external interface for serial communication is RS-
232C DCE (Data Communication Equipment) whose
connector form is D-sub 9pin(male).
When connecting the XCI-SX1/V3 to a PC, use a cross
cable.
TXD 1
RXD 2
GND 3
NC 4
NC 5
NC 6
1–
2 RXD
3 TXD
4–
5 GND
6–
7–
8–
9–
XCI-SX1/V3 RS-232C connection
6PIN
D-SUB 9PIN
Telnet Communication
Specifications
The following table shows the specification for telnet
communication.
Port Number 23
Authentication login, password authentication
For the login, use the following login account.
user: admin
password: 1227
Telnet Authentication
Specification
When you access the XCI-SX1/V3 from external
equipment, the following message appears on the
monitor.
SMARTCAM Telnet Server
SMARTCAM login:
Enter the login account and then the password.
SMARTCAM Telnet Server
SMARTCAM login: admin
password: ******