3.2. Ad ju sting the suc ti on pi pes
The suc ti on pi pes have to be ad jus ted ex act ly to en su re trou ble free ope ra ti on.
1. Set the suc ti on pi pes to their home po si ti on.
&
At home po si ti on the in ner pipe of the suc ti on pipe pro tru des about
120-160 mm (4.75" - 6.25") from the ou ter pipe at the top end.
2. Start a con vey ing ope ra ti on.
Con nect the unit to mains supp ly by the de vi ce plug.
3. Ob ser ve the fle xi ble hose at the suc ti on pipe.
The fle xi ble hose must not show any pul sa ting mo ve ment.
4. Ob ser ve the fle xi ble hose at the se pa ra tor.
The con vey ing hose must only move du ring in-feed.
If the con di tions (points 3 + 4) are not met:
Pull the in ner pipe furt her out of the ou ter pipe un til the re is no more jer ky con vey an ce.
If the con di tions (points 3 + 4) are met:
Push the in ner pipe slowly into the ou ter pipe un til pul sa ting of the fle xi ble hose or shock con vey -
an ce oc curs.
Now pull the in ner pipe slight ly back again un til the hose stop pul sa ting.
Se lect a set ting bet ween the two pi pes to en su re that enough air can flow into the ma te ri al pipe.
Once you have rea ched a sa tis fac to ry con vey ing re sult turn the wing screw at the suc ti on pipe
tight.
516-4MS
SSE-2
Put ting into ope ra ti on 3-3