6.1. Ge ne ral
The sing le con vey or unit functions ac cor -
ding to the prin ci ple of suc ti on con vey an ce.
A high-per for man ce tur bi ne, moun ted per -
ma nent ly on the de vi ce, pro vi des for the
va cu um that is re qui red to con vey the ma -
te ri al into the se pa ra tor.
In the se pa ra tor the ma te ri al is se pa ra ted
from air. Af ter the con vey ing time is fi nis -
hed the tur bi ne is swit ched off and the ma -
te ri al emp tied into the ma te ri al in ter me di -
ate hop per. If the fil ling le vel re mains be low
the out let flap of the sing le con vey or unit, a
star ting pul se is trig ge red and sent to the
con trol ler.
The fil ter will be clea ned (pas si ve clea ning)
or blo wed off using com pres sed-air (op tio -
nal, ac ti ve clea ning). Then the con vey an ce
is res tar ted. This pro cess re pe ats so of ten
un til the ma te ri al in ter me di ate hop per is fil -
led. Af ter wards the con vey an ce is stop ped
un til a new star ting pul se is trig ge red and
sent to the con trol ler.
516-4MS
SSE-2
Functio nal des crip ti on 6-2