TANDBERG F1 D13642.01 Digital Camera User Manual


 
TANDBERG 1500 MXP
92
Ethernet Speed
Auto
The codec will auto-detect the speed/duplex on the LAN.
10/Half
The codec will connect to the LAN using 10Mbps speed/Half Duplex.
10/Full
10 Mbps speed/Full Duplex.
100/Half
100 Mbps speed/Half Duplex.
100/Full
100 Mbps speed/Full Duplex.
IP Access Password
By setting an IP Access Password on the system, all access to the system using IP (Telnet,
FTP and WEB) requires a password. The default IP Access Password is TANDBERG.
4.8.2.2 H.323 Settings
4.8.2.2.1 E.164 alias
This is the E.164 address of the system. The E.164 address is equivalent to a telephone
number, sometimes combined with access codes. Valid characters are 0-9,* and #. When
using a gatekeeper, the system will send a message to the gatekeeper containing both the
E.164 address and the system name of the system. The system will not register with the
gatekeeper if the E.164 alias is not set.
4.8.2.2.2 H.323 Call Setup
Direct
An IP-address must be used in order to make a H.323 call. The system will
not use a gatekeeper or call manager
Gatekeeper
The system will use a gatekeeper to make a H.323 call (the system will still
be able to place calls directly to an IP-address without using the
gatekeeper).
Call
Manager
The system will use a call manager to make a H.323 call (the system will
still be able to place calls directly to an IP-address without using the call
manager).
4.8.2.2.3 Gatekeeper Discovery
Auto
The system will automatically try to register on any available gatekeeper. If a
gatekeeper responds to the request sent from the codec within 30 seconds this
specific gatekeeper will be used. If no gatekeeper responds, the system will not