8.4
On Screen RS422 setting menu (FOR REMOTE CONTROL)
The camera is adjusted using a sub menu for setup using a remote control.
Press and hold the switch on the side of the camera body 2 seconds until the menu
appears on the monitor. The blinking area represents the option to be set.
(This sub menu cannot control from a keyboard by RS-422)
Default settings
ADDRESS 00 1
PROTOCOL TOSH I BA - P
BIT-RATE 4800
ADDRESS 0 0 1
PROTOCOL TOSHI BA - P
BIT-RATE 4800
VERS ION
****
EXIT DEFAULT
(2) PROTOCOL
ADDRESS 0 0 1
PROTOCOL TOSHI BA - P
BIT-RATE 4800
VERS ION
****
EXIT DEFAULT
(3) BIT-RATE
ADDRESS 0 0 1
PROTOCOL TOSHI BA - P
BIT-RATE 4800
EXIT DEFAULT
(4) VERSION
Software version display.
(1) ADDRESS
Move the cursor to the position in Fig.
Use the SELECT switches to select 001
to 255.
In RS-422 control, it is necessary to set a
unique camera address for each camera.
Move the cursor to the position in Fig.
Use the SELECT switches to select
TOSHIBA-P, TOSHIBA-D.
Move the cursor to the position in Fig.
Use the SELECT switches to select 1200,
2400, 4800, 9600bps.
In RS-422 control, the bit rate for each cam-