360014937
Copyright © 2000 Toshiba corporation. All rights reserved.
-
595 -
BYTE 362: Off-line data collection status
Value Definition
00h or 80h Off-line data collection activity was never started.
01h Reserved
02h or 82h Off-line data collection activity was completed without error.
03h Reserved
04h or 84h Off-line data collection activity was suspended by an interrupting command from host.
05h or 85h Off-line data collection activity was aborted by an interrupting command from host.
06h or 86h Off-line data collection activity was aborted by the device with a fatal error.
07h-FFh Reserved
BYTE 363: Self-test execution status
The self-test execution status byte reports the execution status of the self-test routine.
Bits 0-3 (Percent Self-Test Remaining) The value in these bits indicates an approximation of the
percent of the self-test routine remaining until completion in ten percent increments. Valid values are
0 through 9. A value of 0 indicates the self-test routine is complete. A value of 9 indicates 90% of
total test time remaining.
Bits 4-7 (Self-test Execution Status) The value in these bits indicates the current Self-test Execution
Status .
Self-test execution status values
Value Description
0 The previous self-test routine completed without error or no self-test has ever been run
1 The self-test routine was aborted by the host
2 The self-test routine was interrupted by the host with a hard or soft reset
3 A fatal error or unknown test error occurred while the device was executing its self-test
routineand the device was unable to complete the self-test routine.
4 The previous self-test completed having a test element that failed and the test element
that failed is not known.
5 The previous self-test completed having the electrical element of the test failed.
6 The previous self-test completed having the servo (and/or seek) test element of the test
failed.
7 The previous self-test completed having the read element of the test failed.
8-14 Reserved.
15 Self-test routine in progress.
BYTE 364-365: Total time
The time for off-line data collection operation ( sec.)
BYTE 366: Reserve
BYTE 367: Off-line data collection capability
bit 0 (Execute off-line immediate implemented bit)
bit0 = 1 SMART EXECUTE OFF-LINE IMMEDIATE command supported.
bit0 = 0 SMART EXECUTE OFF-LINE IMMEDIATE command NOT supported
This bit is set to 1
bit 1 Reserved
bit 2 (abort/restart off-line by host)
bit2 = 1 If another command is issued, off-line data collection operation is aborted.
bit2 = 0 If another command is issued, off-line data collection operation is interrupted and then
the operation will be continued.
bit 3 (off-line read scanning implemented bit)
If this bit is cleared to zero, the device does not support off-line read scanning. If this bit is set to
one, the device supports off-line read scanning. This bit is set to 1.