8. Make sure the sprayer is earthed (grounded). All sprayers are
equipped with a earthing (grounding) cable (1). Clip the end
of the grounding cable to a true earth ground.
1
9. Strain all paints with a nylon strainer to ensure trouble free
operation and freedom from frequent cleaning of the inlet
screen and gun lter.
10. Make sure the spray area is well ventilated to prevent
hazardous operation with volatile solvents or exhaust fumes.
If lacquer or other flammable materials are to be
sprayed, ALWAYS locate the compressor outside the
immediate spraying area. Failure to do so may cause
an explosion.
11. Locatethecompressoroutsidetheimmediatesprayingarea
to avoid clogged air intake of the compressor with overspray.
4.2 Automatic Lubricator
The automatic lubricator (Fig. 10, item 1) provides lubrication to the
air that is being delivered to the system. It is set at the factory for the
correct injection rate and should not be adjusted until the reservior
needstoberelledwithAirCare™lubricant.Checkthelevelthrough
the openings (2) in the side of the air motor shroud.
After relling the reservoir, the automatic lubricator will need
adjusting. Turn the adjusting screw (1) clockwise to increase the
AirCare™injectionrateandcounterclockwisetodecreaseit.
1
2
Check the injection rate by observing the ow through the openings
in the side of the air motor shroud.
• Theproperowrateis1dropofAirCare™perminute.
• Incoldweatherwhenicingmayoccur,increasetheinjection
rate.