Technical Specications
Function Pin Notes
Specications
GND
1
Ground
3.3 V DC P ower
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
Max load = 250 mA
Digital input — Connect to GND to activate, or leave oating
(unconnected) to deactivate.
0to+40VDCCongurable
(Input or Output)
3–6
Digital output Internal connection to ground when
activated, oating (unconnected) when deactivated. If used
with an external relay, a d iode must be connected in parallel
with the load, for protection against voltage t ransients.
Max load =100 mA
Max voltage = +40 V DC