System Options
1. Disconnect power from the product.
2. Press and hold the C ontrol button and reconnect power (see
Hardware Overview, on page 4
).
3. Keep the Control button pressed for about 15 seconds until the Status indicator ashes amber.
4. Release the Control button. The process is complete after about 1 minute (when the Status indicator turns green). The
product has been reset to the factory default settings. The d efault IP address is 192.168.0.90
5. Re-assign the IP address.
It is also possible to reset parameters to factory default via the web interface. Go to Setup > System Options > Maintenance.