Bosch Appliances 500 Security Camera User Manual


 
MIC Series 500 Camera Navigating the Menus | en 25
Bosch Security Systems, Inc. User’s Manual F.01U.173.601 | 2.0 | 2010.11
The Config settings are available through the menu and offer the user a quick way of
setting up the MIC 500 Series Camera for different configurations. Table 5.2 and
Table 5.3 indicate the options available and which settings are changed when these are
set.
The settings modified by these (for example, Image Flip, Pan Reverse, Auto Alarm, etc.)
can also be individually set elsewhere in the menu; however the “Config” settings retain
their current value, which may lead to confusion over the current MIC 500 Series Camera
state. It is advised that the individual settings are not changed unless specifically
required.
Table 5.1 MIC 500 Series Camera Settings and Options
AUTO FLIP When enabled this command automatically flips the video picture and PTZ controls to enable
easy control when the camera is inverted. Controls remain reversed until a stop command is
received, at which point they return to normal.
SELF DIAGNOSIS Runs rudimentary tests indicating any faults with the unit. The test begins with the unit moving
to a specified test position and then checking for valid resolver readings and reliable camera
module communications. Then, the pan and tilt drives and camera zoom are tested. Finally, the
wiper is activated. The results of each test are displayed as completed, refer to Section 5.16 Self
Diagnosis, page 50.
Menu Item Description
Setting Options Default
Config Upright/Canted/Inverted UPRIGHT
Auto Home ON/OFF OFF
Home To Preset/Tour TOUR
Wash-Wipe ON/OFF OFF
OSD ON/OFF OFF
Pos Display ON/OFF OFF
Auto Alarm ON/OFF OFF
Digital Zoom ON/OFF OFF
Auto Flip ON/OFF OFF
Self Diagnosis N/A