46 en | Navigating the Menus MIC Series 500 Camera
F.01U.173.601 | 2.0 | 2010.11 User’s Manual Bosch Security Systems, Inc.
remove the privacy mask for the complete video picture as it is currently viewed. Manual
control works as in the Preset sub menu, giving 10 secs of movement before returning to the
same page, which means all privacy masks can be set through the menu controls.
5.12 Pot Test Menu
The POT TEST menu enables the user to view the current position, motor readings, and
internal PSU level of the unit.
When Start is selected, a screen indicating current pan and tilt positions and their respective
motor PWM readings appears. At the bottom of the screen, the current internal voltage is
displayed in Volts. To cancel the test, send a left command and then left again to return to the
main menu.
5.13 MIC Information Menu
The MIC Information menu provides access to a number of statistics which are recorded in
the memory of the MIC 500 Series Camera, mainly for engineering purposes. These statistics
can be viewed through the on-screen menu or Cam-set, but cannot be cleared without a
password from the manufacturer.
MAIN MENU 2/2 POT TEST POT TEST
SONY SET SPEED 50
CAPTIONS DIRECTION LEFT PAN : TILT
PRIVACY POS : PWM : POS: PWM
POT TEST START __________________________
MIC INFORMATION 3507:159 :700 :400
ENTER PASSWORD
HELP PSU : 17.7 V
EXIT
Menu Item Description
SPEED Sets the speed of the unit for the POT test (range 1-255).
DIRECTION Sets the direction of the unit for the POT test (options Left, Right, Up, Down).
START Initiates the Pot Test process. Continual commands are sent requesting the MIC 500 Series
Camera current data, the responses are decoded and data printed and plotted on the display.
PAN : TILT Indicates the current position in Pan and Tilt in Red and Blue respectively, over the range of 4096
units for 360 degrees rotation.
PWM Indicates the current PWM (Pulse Width Modulation) of the motor with Pan and Tilt being
indicated in Green and Purple respectively. This indicates how hard the motors are working.
PSU Level Shows the Voltage level of the main power rail in the MIC 500 Series Camera.
MAIN MENU 2/2 .. MIC INFO 1/15 .. .. MIC INFO 2/15 ..
SONY SET
CAPTIONS OFF GENERAL MIC INFO GOTO PRESET MAPPING
PRIVACY OFF ADDRESS : 1 WIPER ON N/A
POT TEST SOFTWARE : 500 A 1.00P WIPER OFF N/A
MIC INFORMATION PROTOCOL : BOSCH WASHER ON N/A
SET USER ACCESS BAUDRATE : 9600 WASHER OFF N/A
HELP COMMS :NONE, 8, 1
EXIT 044452198803010002
CAM ZOOM :18X DIG. ZOOM ON N/A