Bosch Appliances UPH-Z Security Camera User Manual


 
12 en | Installing the High Speed Pan/Tilt High Speed Pan/Tilt System
F01U.073.990 | Version 1.0 | 2007.07 Instruction Manual Bosch Security Systems
3. Attach the optional wall or pole mount according to the specific mounting manual (see
Table 4.1 for mounting options).
Table 4.1 Mounting Options
4. Remove the cable glands from the base and fit the gasket / seal ring (see Figure 4.3).
5. Insert the cables into the cable glands while holding the base approx. 20 cm from the
bracket (see Figure 4.2). Note that there are three glands; one for power, one for video,
and one for data / IO cables.
Fig. 4.2 Inserting the Cables through the Cable Glands
6. Securely lock the cable glands into place (gland closing torque 5 Nm); they accept cables
5-10 mm in diameter. The cable glands can be changed to accept smaller 3-7 mm in diam-
eter cables, available from www.cembre.com and browse "Cable glands IP68 MAXIblock"
(model number: 1910.M16 M16x1.5 ). The gland (5-10 mm or 3-7 mm) closing torque is
5 Nm; use a calibrated torque wrench to ensure closure.
7. Position the base on the optional wall or pole mount, guiding the cables so that they are
positioned inside the wall or pole mount (see Figure 4.3).
!
CAUTION! Medium Risk:
Be sure to use appropriately strong and load bearing bolts and other fixing
materials when installing any UPH mountings to any surface.
When the MTC-WUPH Wall Mount is fixed to a wall, each fixing dowel must be
able to support a traction load of 300daN or more. It is necessary to use 8 mm
(0.315 in.) diameter bolts with appropriate length.
Part # Description
MTC-PUPH Outdoor Pole Mount for UPH Series
MTC-WUPH Outdoor Wall Mount for UPH Series
MTC-POLE-W Pole Adapter for MTC-WUPH
MTC-CORN-W Corner Adapter for MTC-WUPH
i
NOTICE!
If using a washer kit, the spray support should be installed before positioning
and wiring the pan/tilt. For additional information, see Section 5 Connecting
the Washer Pump (optional).
7