Bosch Appliances UPH-Z Security Camera User Manual


 
High Speed Pan/Tilt System Configuring the System | en 53
Bosch Security Systems Instruction Manual F01U.073.990 | Version 1.0 | 2007.07
Focus Parameters Menu
The Focus Parameters menu is used to enable focus settings.
FOCUS PARAMETERS MENU
1 - MANUAL SPEED 005
2 - AUTOFOCUS TYPE TRIG
3 - SENSIBILITY HIGH
4 - AUTOFOCUS YES
5 - FOCUS MIN. LIMIT 150
Fig. 11.22 Focus Parameters Menu
Feature Description Default Options
MANUAL SPEED The speed can take values
between zero (0) minimum speed
and seven (7) maximum speed.
005 0-7
AUTOFOCUS TYPE Normal: standard operating mode
for auto focus.
Interval: load the auto focus func-
tion at intervals. Loading is set at
every five (5) seconds.
Trigger: load auto focus whenever
the zoom or pan and tilt move-
ments move and return to manual
focus.
TRIG NORM,
INTER, TRIG
SENSIBILITY High: focusing at the higher speed.
Low: slower focusing. This is use-
ful when the lighting is poor
because it makes the image more
stable.
LOW AUTOMATIC
or MANUAL
AUTOFOCUS MANUAL MODE: the user always manually adjusts the exposure
via the iris buttons.
AUTOMATIC MODE: the exposure normally stays in automatic
mode. Moreover, the user can override the exposure manually
via Iris.
FOCUS MIN LIMIT Set the minimum object distance
for focus (cm).
150 016 - 192