4-4
The VB-C300 Log Messages
The log messages are classified into the following five categories.
Log Messages
■ Camera Messages
● A001 Camera start failure (crit)
● A002 Protocol initialization failure (err)
● A011 Camera control device error (warning)
● A012 WebView Livescope client start and stop (info)
● A016 Video data transmission quantity (info)
Classification Level Error level
crit Error A critical failure at software level (task stops).
err Error A failure affecting camera operation (task continues).
warning Warning A failure not affecting the camera operation.
notice Warning A failure external to the system.
info Information Information concerning normal operation.
Message no %1 installed
%1 sources | protocols
Explanation Camera failed to capture images or initialize the protocol and could not start.
Countermeasure Reboot the camera. If the problem persists, it is a camera failure. Call for service.
Message %1 protocol not installed
%1 Protocol type (LS/H)
Explanation The camera failed to initialize the WebView. Configuration data may be destroyed.
Countermeasure Restore the factory default settings or press the Reset switch.
Message %1@%2 %3
%1 Client type (LS/H)
%2 Client host IP address
%3 connected | closed
Explanation The HTTP WebView client (LS/H) has started or stopped.
Message %1@%2 %3 frames / %4 bytes in %5 seconds
%1 Client type (LS/H)
%2 Client host IP address
%3 Number of frames
%4 Number of bytes
%5 Video transmission period
Explanation This message indicates the results of video transmission to the client.
Message %1 malfunction (%2)
%1 Camera type (Canon VB-C300NA | Canon VB-C300PA)
%2 Error (read | write | timeout | ...)
Explanation An I/O error for the camera control device has occurred.