Canon VB150 Security Camera User Manual


 
Appendix
c
Note
Be sure to make a note of the current settings before you restore the
factory default settings using the Restore button ( P.114, 115).
Once the Factory Defaults Reset switch is pressed, the VB150’s network-
related settings, such as the IP address, subnet mask, and default gateway
address will return to their factory default values, making it impossible to
operate the VB150 from a PC connected to it. In this event, reset the IP
address for your environment ( P.31).
Restoring the Factory Default Settings
There are 2 ways to restore the factory default settings on the VB150, as described below. When
you restore the factory default settings, the procedure in “Initializing settings other than system/
network settings” resets all the settings except the system settings ( P.37) and the network
settings ( P.38). The procedure in “Initializing all settings” resets all the settings to their factory
default values.
Initializing settings other than system/network settings
Launch the Web browser to access the VB150 Settings Title Page ( P.36) and open the
Administration Tools Settings Page ( P.59). Click the Restore button to restore all the factory
default settings, except for the System ( P.37) and Network ( P.38-41) settings. Note that
once this button is clicked, the VB150 will restart automatically to restore the settings so that you
cannot cancel the process.
This button can be used when the VB150 is accessible via the network. Use this button when you
want to restore the settings other than the System and Network settings.
Initializing all settings
Unplug the AC adapter to turn the VB150 off. Use a pointed object such as the end of a paper clip
to press the Factory Defaults Reset switch and then plug the AC adapter to turn the VB150 on. Be
sure to hold down the Factory Defaults Reset switch for at least 5 seconds after the power is
turned on. All VB150 settings will return to the factory default values, but the content of Web
pages used for distributing videos that is saved on the VB150 will remain as is. Note that once the
process is executed, it cannot be canceled.
Use the Factory Defaults Reset switch when you have forgotten the password or IP address and
that you cannot access the VB150 via the network.
VB150 rear panel
Factory Defaults Reset switch
D
c
In
1
3
V
In
O
u
t
1
0
0
/1
0
B
T
C
C
1
R
S
2
3
2
C
V
id
e
o
In
E
th
e
rn
e
t
C
C
2
V
1
V
2V
3
V
4
S
lo
t-A
S
lo
t-B
12
2
1
A
B
A
B
112