Cisco Systems 6020 IP Security Camera User Manual


 
2-12
Cisco Video Surveillance 6020 IP Camera Installation Guide
OL-28120-02
Chapter 2 Camera Installation
IP Camera Installation
Note The mini cable with BNC adapter is included in the audio/video cables accessory kit, which you can
purchase from Cisco (Cisco part number CIVS-AVCABLE).
Analog video is enabled by default to allow you to adjust the camera field of view during installation.
However, it is not supported as a normal camera feed and is automatically disabled when any of the
following camera settings are made:
The primary video stream frame rate must be set higher than 15 fps.
The secondary video stream must is enabled.
Note We recommend that you disable analog video after installation. To disable analog video, see the Cisco
Video Surveillance 6000 Series IP Camera Configuration Guide.
Step 9 Remove the black cover.
Step 10 While viewing video from the IP camera, perform the following steps to adjust the 3-axis field of view:
a. Grip the two tilt adjustment screws and pan the IP camera left or right.
b. Loosen the two thumb screws, tilt the IP camera, then tighten the thumb screws.
c. Rotate the IP camera to adjust the image horizontal orientation.
Step 11 After you have adjusted the field of view, focal length, and zoom factor, install the black cover. Make
sure to adjust the it so that it does not block the lens from capturing video.