3.3.12 ALARM SETTING
The integrated high speed dome provides eight alarm inputs and two alarm outputs (N.O.
and N.C) to connect alarm devices. With this function, dome will cooperates with alarm
system to catch the event images. For wiring, please refer to the installation guide
and/or qualified service personnel. Alarm parameters can be set on this page.
ALARM SETTING
ALARM PIN 1
ALARM SWITCH OFF
ALARM TYPE N.C.
ALARM ACTION PRESET
PRESET POINT 001
DWELL TIME ALWAY
EXIT YES
ALARM PIN
The dome provides 8 alarm inputs and 2 outputs (1× N.O. and 1× N.C.). Select an
alarm connector which you want to set its alarm-related parameters with this item,
and then set its alarm-related parameters in Alarm Setting menu. For alarm pin
definitions, please refer to section
2.6 Alarm Pin Definition or installation guide.
ALARM SWITCH
The item is used to enable or disable the selected alarm pin function. Use the
left/right direction keys on the control keyboard to change the setting.
ALARM TYPE
There are two kinds of alarm types: Normal Open and Normal Close, which are
illustrated as below. Select an alarm type that corresponds with the alarm
application.