(2) EXPOSURE SET.
In this menu, the exposure system of the camera can be specified.
There are 2 kinds of EXPOSURE SET. menu.
A. AE MODE other than MANUAL B. MANUAL is selected for AE MODE
Fig. 8-1 EXPOSURE SET. menu
AE MODE
AE operation mode can be selected.
WD → NORMAL → BLC → MANUAL The mode turns in this order.
WD : Wide Dynamic Range function operates.
This function is used under shooting conditions in which there is a mixture of high-luminance and
low –luminance subjects. When this mode is selected, E-ZOOM is not available.
NORMAL : This mode is AE operation which is controlled by the electronic shutter and mechanical
iris.
BLC : This mode offers a Back Light Compensation function.
This mode allows fine picture correction to prevent the subject from being extremely dark due to
strong backlight.
MANUAL : The electronic shutter speed can be selected. Refer to SHUTTER SPEED.
LEVEL
The video output level can be adjusted. (Adjustable range : -5 ~ 5)
Note) When BLC is selected for AE MODE, the level can’t be adjusted.
FLICKERLESS
When AE MODE other than MANUAL is selected, this item appears on the menu.
When ON is selected, the shutter speed is fixed at 1/100s (NTSC) or 1/120s (PAL).
SHUTTER SPEED
When MANUAL is selected for AE MODE, this item appears on the menu.
1/60(NTSC), 1/50(PAL), 1/100(NTSC), 1/120(PAL), 1/250, 1/500, 1/1000, 1/2000, 1/4000,
1/10000, 1/20000, 1/50000
AGC
AGC automatically controls the gain in low-brightness zones.
This function can be switched ON or OFF.
SENS UP
This function offers optimal brightness level by increasing the number of stored fields.
Refer to the following value.
OFF, 2, 4, 6, 8, 10, 20, 40
Note) When MANUAL is selected for AE MODE, OFF is automatically selected for SNES UP.
While SENS UP is selected, noise spots, blemish of CCD or a whitish phenomenon may
appear in the picture. This is a normal phenomenon.
EXPOSURE SET.
AE MODE
LEVEL
FLICKERLESS
AGC
SENS UP
DAY&NIGHT
DETECT TIME
FILTER LIMIT
RETURN END
EXPOSURE SET.
AE MODE
LEVEL
SHUTTER SPEED
AGC
SENS UP
DAY&NIGHT
DETECT TIME
FILTER LIMIT
RETURN END
→ WD
→ 0
→ OFF
→ ON
→ 4
→ AUTO
→ 5 sec
→ 10min
→ MANUAL
→ 0
→ 1/60
→ ON
→ OFF
→ AUTO
→ 5 sec
→ 10min
En-15