TruVision Mini PTZ 12X Camera 11
Pocket Guide
Setting the dome camera site ID
Before turning on the dome camera, you must set the dome
camera site ID. Each dome camera connected to the same
network must have a unique site ID. Use the 10-bit DIP switch
to set the dome camera site’s ID setting.
For more detailed information on setting the dome camera site
DIP switches, please refer to the user manual.
Figure 3: Example of setting DIP switches for the dome
camera site ID 210 (128 + 64 + 16 + 2)
To set a dome camera site ID
1. Locate the dome camera site ID DIP switch block (E,
Figure 1 on page 9).
2. Determine which DIP switches when turned on will add up
to the site ID number for that dome camera. See Figure 3
above for an example.
3. Place the switches that correspond to those values in the
On position.
4. Carefully record the site ID of each dome camera
installed.