JAI CV-M10 Security Camera User Manual


 
CV-M10BX/CV-M10RS
- 11 -
8. Jumper settings
Switch off the power before making any mode or jumper settings.
The following modes are available with jumper setting:
Input/Output Mode of HD/VD signal. (HD/VD input is factory setting)
Termination of HD/VD input. (75 ohm is factory setting.)
Trigger input termination. (Factory setting is TTL)
Trigger mode select. (Edge Pre-select is factory setting)
H-reset or H non-reset. (Fatory setting is H reset.)
Alternative pins for inputs/outputs.
Jumper settings in "italic bold" are factory setting.
8.1. HD/VD signals
Jumpers on PK8189A.
8.2. Trigger input termination
Jumper on PK8206A for BX or PK8190A for RS.
8.3. Trigger mode selection
Jumpers on PK8206A for BX or PK8190A for RS.
8.4. Pixel clock or video 2 on pin 9 (12 pin con.)
Jumpers on PK8187A.
*) Note: For Pulse Width Control, shutter speed must be set to 1/10,000 sec. (For BX by SW1. For RS by RS232C)
8.5. Alternative input/outputs on pin #6 and #7 (12 pin con.)
Jumpers on PK8187A.