Page 32
TM-1020 Series Progressive Scan Shutter Cameras
Operation
Model: TM-1020-30 Operation Mode: 30 Frames/Second
Master Clock: 80 MHz, M= 12.5 nsec
Pixel Clock: 40 MHz, P = 25 nsec
3. External Reset Timing
4. Async Shutter 0 Reset Timing
External VD
Internal VD
FDV
Digital Data
Analog Video
VINIT Trigger
Internal VD
FDV
Digital Data
Analog Video
Horizontal Frequency: 31.50 KHz
1H = 31.75 sec
A [1050 H], (33.34 msec)
B [0, H], (0 us)
C [9 H], (285.75 s)
D [1041 H], (33.05 ms)
E [1050 H], (33.33 ms)
K [3 H], (97 ns)
F [32 H], (1.02 ms)
H [32 H], (1.02 ms)
J [29 H], (0.92 ms)
L [3 H], (97 s)
G [1018 H], (32.32 ms)
I [1018 H), (32.32 ms)
M [1018 H], (32.32 ms)
P [1041 H], (33.05 ms)
Q [ 1050 H], (33.34 ms)
T [1018], (32.32 ms)
X [1018 H], (32.32 ms)
N [1 H], (31.75 s)
U [29 H], (0.94 ms)
S [32 H], (1.02 ms)
W [3 H], (97 s)
V [3 H], (97 s)
O [9 H], (286 s)
R [32 H], (1.02 ms)