Item
AE DISPLAY
FRZ DISPLAY
FRZ CANCEL
TEST PATTERN
LEVEL
When BAR/
IMPULSE
is selected
MENU RESET
SYSTEM SETTING screen
5. Menu screen settings (continued)
[ ] indicates the factory setting
Set Value
[OFF]
ON
[ON]
OFF
[MANUAL]
AUTO (1s)
AUTO (3s)
AUTO (5s)
OFF
[BAR]
RAMP
IMPULSE
[0.7V]
0.57V
Contents
Used to set whether the ALC, EEI and IRIS values are
displayed on the analog output screen.
OFF: No on-screen-display
ON: On-screen-display
Used to set whether the
FREEZE indicator is shown on
the screen at the time of trigger input.
ON: Displayed
OFF: Not displayed
Sets the method for canceling the FREEZE when the
monitor screen is in FREEZE condition when connection
is made through digital output.
MANUAL : Cancelled by trigger input.
AUTO(1s) : Cancelled after 1 second.
AUTO(3s) : Cancelled after 3 seconds.
AUTO(5s) : Cancelled after 5 seconds.
OFF : Not cancelled.
* When set to AUTO or OFF, the displayed screen can
be updated by trigger input during the FREEZE condi-
tion.
Sets the test pattern type output when the function set-
ting switch No.1 <TEST PATTERN> is set to
ON.
BAR : BAR pattern is output.
RAMP : RAMP pattern is output.
IMPULSE : IMPULSE pattern is output.
Sets the level of the color signal bar output from the KY-
1030s [ANALOG OUT] connector.
0.7V: 0.7V test signal is output
0.57V: 0.57V test signal is output
Resets all the set values of menus to the initial values.
page E43, Resetting menu settings
E41
MENU (QUICK) screen
[ ] indicates the factory setting
Item
AE LEVEL
IRIS LEVEL
SHUTTER
SPEED
When
STEP is
selected
Set Value
128
127
[0]
126
127
0
1
[255]
[STEP]
V.SCAN
RANDOM
EEI
OFF
4s
2s
1s
1/2s
1/4s
[1/8s]
1/15s
1/30s
1/60s
1/125s
1/250s
1/500s
1/1000s
1/2000s
Contents
Used to adjust the video level when using auto iris, ALC
and EEI.
Increase the number : raise the level
Decrease the number : lower the level
Used to set the iris level when the IRIS MODE is set to
MANUAL.
Increase the number : open iris
Decrease the number : close iris
Used to switch the shutter mode.
STEP: The shutter speed can be changed with the
[SPEED] item.
V. SCAN: The shutter speed can be changed with the
[SPEED] item.
Enables more detailed setting than [STEP].
RANDOM: Used to synchronize the CCD accumulation
timing with the trigger input.
The shutter speed can be changed with the
[SPEED] item.
EEI: Used to automatically change the shutter
speed in accordance with the brightness of the
subject.
OFF: Fixed at 1/7.5 s.
The shutter speed can be changed when SHUTTER is
set to STEP, V
.SCAN or RANDOM.
MEMO
---- is displayed when auto iris, ALC, and EEI are all set to
not work.