Note
The “AE LEVEL”, “AE DETECT” and “AE AREA” items cannot be selected when operation of auto iris, “ALC”
and “EEI” are set as disabled.
The “AE LEVEL” and “AE DETECT” items are displayed as “- - - - - -”.
“ADVANCED EXPOSURE” Screen
Settings in bold are factory settings
Function/Variable Values
For setting the maximum “ALC” value that triggers automatic switching of gain
boost level according to the brightness.
{Variable Values : +9, +12, +15, +18 dB}
For setting the maximum shutter speed when shutter mode is set to “EEI”.
1/240 : Set as 1/240 seconds.
1/480 : Set as 1/480 seconds.
1/960 : Set as 1/960 seconds.
For adjusting the image level when using auto iris, “ALC” or “EEI”.
Increase value : Increases level.
Decrease value : Decreases level.
{Variable Values: –5 - 0 - +5}
Selects the detection method of the detection area when auto iris, “ALC” or “EEI”
is used.
“NORMAL” : Normal Position
“PEAK” : Detects the maximum brightness value (peak level) to
enhance visibility of objects with high luminance.
“AVG” : Detects the average brightness value (average) to enhance
visibility of objects with high luminance.
Invokes the “AE AREA” screen.
For selecting the detection area of the image level when using auto iris, “ALC” or
“EEI”.
Press the [SET] button to return to the “EXPOSURE” screen when cursor is at this
position.
Detection Area
“SQUARE”
“CIRCLE”“FULL”“SPOT”“NORMAL” “RECTANGLE”
Detection Area
Detection AreaDetection Area
Detection Area
Detection Area
Item
“ALC LIMIT”
“EEI LIMIT”
“AE LEVEL”
“AE DETECT”
“AE AREA..”
“PAGE BACK”