JVC VN-C215V4U Digital Camera User Manual


 
27
Alarm Input
Connect this terminal to sensor devices, such as
an infrared sensor, door sensor, metal sensor,
manual switch, etc.
Input requirements
No-voltage relay NPN open collector input
Polarity of input detection can be selected
using a software
Make/Break (500 ms and above)
Circuit current at low level: 0.3 mA
Applied voltage at high level: 3.3 V
Alarm Output
Connect this terminal to annunciating devices,
such as annunciators, indicators, lights, buzzers,
etc.
Output requirements
Equivalent to NPN open collector output (Set
the output put logic via the Internet Explorer)
Allowable applied voltage: DC12 V and below
Allowable inflow current: 50 mA
Momentary (100 ms - 5000 ms) output
(Set time via the Internet Explorer )
Note
Connect the GND cable of this camera to the
GND of the annunciating device.
When the camera is mounted, adjust the image
settings while looking at the actual image.
Mounting the test monitor
Connect the [MONITOR] terminal of the camera
to the test monitor to adjust the camera shooting
direction, field angle and focus.
T When configuring, turn on the power of the
camera.
DC3.3 V
R
3.3 V
0.3 mA
VCC
OUT
GND
GND
OUT
R
GND
(Alarm input equivalent circuit)
Input 1
or Input 2
S
ensor
example (1)
Sensor
example (2)
Relay switch etc.
Camera unit
IN
R
DC 12 V
GND
GND
annunc
i
at
i
ng
devices
(Alarm output equivalent circuit)
Output 1
or Output 2
Camera unit
Image adjustment
[MONITOR]
terminal
75 K terminated
Test monitor
VN-C215_EN.book Page 27 Monday, November 27, 2006 9:52 AM