Olympus E-P2 Camcorder User Manual


 
103
EN
7
Customizing your camera
ISO STEP
You can select the EV step of the ISO sensitivity from [1/3EV] or [1EV].
ISO-AUTO SET
You can set the upper limit and default ISO values when ISO is set to [AUTO].
[HIGH LIMIT]
This sets the upper limit of the ISO value that automatically changes. The upper limit
can be set from 200 to 6400 in 1/3 EV increments.
[DEFAULT]
This sets the value to be normally used when the optimum exposure can be obtained.
The value can be set from 200 to 6400 in 1/3 EV increments.
ISO-AUTO
You can set the shooting mode in which the ISO [AUTO] setting is activated.
[P/A/S]
The [AUTO] setting is activated in all shooting modes except M mode. When
[AUTO] is selected in M mode, ISO 200 is set.
[ALL]
The [AUTO] setting is activated for all shooting modes. The ISO is automatically
selected to obtain the optimal ISO even in M mode.
BULB TIMER
You can select the maximum time (in minutes) for bulb shooting.
ANTI-SHOCK z
You can select the interval between fully pressing the shutter button and releasing the shutter
to be anywhere from 1/8 to 30 seconds.
This diminishes camera shake caused by vibrations. This feature is useful in situations such
as microscope photography and astrophotography.
x Notes
Anti-shock is added to the shooting functions individually (single-frame shooting, sequential
shooting and self-timer shooting). g“Sequential shooting” (P. 56)
BRACKETING
The camera automatically shoots a number of pictures at different exposure values for each
frame.
[AE BKT] gP. 45
[WB BKT] gP. 71
[FL BKT] gP. 64
[ISO BKT] gP. 47
s0026_e_00_0_unified.book Page 103 Tuesday, September 29, 2009 10:30 AM