Panasonic AK-HCU200P Camera Accessories User Manual


 
12
SETTING2 Screen
This is the selection screen for the SETTING2 menu
Moving the cursor to the “SETTING2” menu title and then pressing the
SELECT dial redisplays the OPERATION menu one level up
SETTING2
FS DELAY NORMAL
HD BAR SELECT ARIB
BAR LPF 7TAP
BAR USER1 75%WHITE
BAR USER2 0%BLACK
SETUP 7.5% OFF
PATHO OFF
indicates the factory default setting
Item
Setting
value
Remarks
FS DELAY
NORMAL
SHORT
Select the delay mode for the HD return
signals
NORMAL:
Matches return signal input that does
not match the sync phase to the
phase of the camera by delaying it by
1 frame
SHORT:
Sets the shortest delay (5 H)
However, if the following conditions
are not met, it is delayed by
1 frame + 5H
HD signal
The SD-HD V item in the HD/SD
PHASE screen is “ADVANCE” or
“0H_SD_DLAY”
When output from this unit is used
as the return signal, the delay is
less than 3H
HD BAR SELECT
FULL
BARS-1
ARIB
BARS-2
BARS-3
BARS-4
BARS-5
BARS-6
Select the color bar signals to be output
from the HD/SD SDI OUT connectors
and VBS connector when “BAR” has
been selected on the operation panel
of the ROP
When they are output in VBS or SD
format, color bars in HD format are
output in the mode specified with
DOWNCONVERT MODE*
FULL:
75 % full field color bar
BARS-1:
Color bar based on the SMPTE
standard
ARIB:
ARIB multi-format color bar
BARS-2:
Color bar based on the EIAJ standard
BARS-3:
Split field color bar
BARS-4:
75 % full field color bar placed in an
area with a 4:3 aspect ratio
(Displayed 40 % gray outside the
area)
BARS-5:
Color bar based on the SMPTE
standard that is placed in an area
with a 4:3 aspect ratio
(Displayed 40 % gray outside the
area)
BARS-6:
Color bar based on the EIAJ standard
that is placed in an area with a 4:3
aspect ratio
(Displayed 40 % gray outside the
area)
Item
Setting
value
Remarks
BAR LPF
OFF
3TAP
5TAP
7TAP
9TAP
Select the filter through which to pass
the color bar signals to be output
from the HD/SD SDI OUT connectors
when BAR has been selected on the
operation panel of the ROP
A higher TAP value will ensure a
smooth rise and fall of the waveforms
and reduce both the overshoot and
undershoot
BAR USER1
75%WHITE
100%WHITE
+I_SIGNAL
–I_SIGNAL
Set user range 1 for when ARIB has
been selected as the HD BAR SELECT
setting
This can be set when “ARIB” is selected
for the HD BAR SELECT item
In the case of another setting, “——”
is displayed and a setting cannot be
selected
BAR USER2
0%BLACK
+Q_SIGNAL
Set user range 2 for when ARIB has
been selected as the HD BAR SELECT
setting
This can be set when “ARIB” is selected
for the HD BAR SELECT item
In the case of another setting, “——”
is displayed and a setting cannot be
selected
SETUP 75%
ON
OFF
Select whether to add the setup 75 %
level to the SD signals to be output from
[OUT/PM] of the VBS connectors
PATHO
ON
OFF
Select ON/OFF for the pathological
signals
*: The DOWNCONVERT MODE setting can be configured by operating
the REMOTE OPERATION menu with the ROP
For details, refer to Operating Instructions <Operations and Settings>
of AK-HRP200
Setting menu items (Continued)