PM OPERATION STATUS Screen
This menu is used to set ON or OFF for the operation items to display
on the picture monitor
indicates the factory default setting
Item
Setting
value
Remarks
STATUS
DISPLAY TIME
0 sec
2 sec
4 sec
Set the length of the status display time
Set the time in 1-second increments
When the status of an item that has
been set to ON on this menu has
changed, the status is displayed on the
picture monitor for just the length of
time that was set for STATUS DISPLAY
TIME
When 0 (zero) is set, the operations
(manual and auto) are not displayed
on the picture monitor
MANUAL OPERATION STATUS
MASTER GAIN
ON
OFF
Set the status display for when the
master gain is changed
SHUTTER
ON
OFF
Set the status display for when the
shutter speed is changed
LENS EXT
ON
OFF
Set the status display for when the lens
extender is changed
FILTER
ON
OFF
Set the status display for when the filter
is changed
SCENE FILE
ON
OFF
Set the status display for when the
scene file is changed
REF LOAD
ON
OFF
Set the status display for when the
reference file is loaded
AUTO
OPERATION
STATUS
ON
OFF
Set the status display for when AWB,
ABB, or ASU is executed
SYSTEM Screen
This menu is used to initialize the menu settings
To return the menu settings to the factory default settings, add a mark
to INITIALIZE and then click [EXECUTE]
The following data is initialized
Items in the OPERATION menu
Items in the MAINTENANCE menu
(Excluding, however, the NETWORK screen, VERSION screen,
SYSTEM screen, and SD CARD screen)
Furthermore, the setting information (following data) in the REMOTE
OPERATION menu* is also initialized
Items in the SD DETAIL menu
Items in the SYSTEM menu
(Excluding, however, each of the HD BAR, MIC1 GAIN, MIC1 AMP,
MIC2 GAIN, and MIC2 AMP items)
*: The REMOTE OPERATION can be operated with the ROP
Web settings (Continued)