Item
Required when installing the mounting
bracket over the wall with the unicorn
anchor
16
Coaxial cable UL Listed NEC type CM or
CL2, RG-6/U type
Recommended distance: 20 m
{65.6 ft.} or less
Use
For connection between an external
video-input device and the iris camera
Connect both ends with BNC plugs.
Power cable
Item number/Recommended type
UL style 1015 (AWG 14-18) or
equivalents
Maximum distance:
10 m {32.8 ft.}
Necessary when supplying power from
the external power-supply device to
the iris camera
Solder both ends of the cable with M3
screw clamp terminals.
LAN cable UL style 1666, CSA-FT4 or equivalents
10 Base-T/100 Base-TX (Category 5)
*
Necessary for communication between
the iris cameras and iris server
Anchor bolt M6
■ Preparation
Prepare the following items before the installation. The necessary items and their lengths differ depending on situation.
● Preparing the Necessary Items
* Only cables without connector covers are usable.
Note: When you use the alarm output and Wiegand terminals, you need optional cables suited for the connectors of the exter-
nal devices. Use the UL style 1571 or equivalents, AWG 22 - 16 wire.
● Cable Preparation
Power cable (with sealing)
■ Notification about the Installation Site
This iris camera is limited to indoor use.
Near-infrared light (contained in sunlight, incandescent light and halogen light) are used for iris image capturing by the iris
camera. If the iris camera is installed in a place which receives this light directly, it may cause invalid iris data
enrollment/recognition, as the camera cannot capture iris images properly.
Keep the iris camera away from the following. Otherwise, light may affect on the iris camera.
• Outdoor places
•Direct sunlight or light reflection
•Incandescent or halogen lighting
•Places where the iris camera or the user's eyes are directly exposed to light
Note: A quantity of acceptable near-infrared ray is 500 µW/cm
2
or less.
•Places near the light reflection (from a mirror, etc.)
•Places where the amount of light is not appropriate for operation
25 mm {1 in.} or less