Pelco C3412M-D Security Camera User Manual


 
68 C3412M-D (12/08)
ALARMS
The Spectra IV SE dome systems have seven alarm inputs that can be programmed as high,
medium, or low priority. When an alarm is received, an input signal to the dome triggers the user-
defined action (go to preset, run pattern, etc.) programmed for the alarm.
Note: Refer to the notation in step 6 for the limited alarm features available for 16X and 18X
models.
There are three global alarm settings:
RESUME: This mode lets the dome resume its previous activity (scan, pattern, or previous
position) after all alarms are cleared.
SEQUENCE: This is the time the dome will perform an alarm activity when more than one alarm
of the same priority occurs at the same time.
RESET DELAY: This is the amount of time the dome considers the alarm to be active after it has
physically cleared.
Use the following steps to program alarm settings.
1. Use the joystick to position the cursor beside ALARM SETTINGS. Press Iris Open.
2. Select the alarm number:
a. Use the joystick to position the cursor beside ALARM NUMBER.
b. Press Iris Open. The cursor moves to the right.
c. Move the joystick up or down to view selections. Press Iris Open to enter selection.
EXIT
SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
BACK
EXIT
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
DOME SETTINGS
BACK
EXIT
ALARM SETTINGS
ALARM NUMBER
ALARM PRIORITY
ALARM ACTION
ACTIVATE AUX
ALARM CONTACT
<EDIT SCHEDULE>
BACK
EXIT
RESUME
SEQUENCE (SECS)
RESET DELAY (SECS)
<ALARM SETTINGS>
ALARMS
*This setting applies only to Pressurized Spectra IV dome systems.