3.0 POWER SUPPLY CONSIDERATIONS
Use only the recommended power supplies. Improper
substitutions may damage the camera or cause a shock
or fire hazard.
CC4600-2/2X
The CC3300-2 must always be operated with a 24
VAC, Class 2 (60 Hz) power supply (not supplied).
A wall transformer (as depicted in Figure 3) is an
example of a common power source.
In the USA, use a power supply which is UL Listed.
In Canada, use a power supply which is CSA Cer-
tified.
The CC4600-2X must always be operated with a
24 VAC (50 Hz) power supply.
When connecting to the transformer, be sure to
carefully connect each lead to the appropriate ter-
minal. Wrong connections may cause malfunction
and/or damage to video camera.
Ground the unit or an irregular voltage may be
generated in the AC power cord and may cause
malfunction or damage to the video camera.
24 VAC Cameras: do not exceed 24 VAC input.
Normal input voltage is 24 VAC
The power runs for user supplied wiring from a 24 VAC
supply to a CC3300-2 camera should be within the fol-
lowing limits:
Up to 60 m (200 ft) — 1 mm
2
(18 AWG) or larger.
Up to 100 m (325 ft) — 1.5 mm
2
(16 AWG) or larger
Do not mistakenly attach the
GND terminal on 24 VAC
cameras to either of the power
terminal inputs. Be sure to use
the grounding lug or screw.
CC4600-3
The CC3300-3 must be always operated with a 220-
240 VAC, (50 Hz) power supply.
NOTE: The CC4600-3 is supplied with an
attached main power cable cord. See Figure 2
legend for power connections.
CC4600-3
POWER CONNECTIONS:
Brown Wire - Hot or Live wire
Blue Wire - Neutral wire
Green and Yellow wire - Earth Ground or GND
3
4
2
76
5
CC4600-2 & -2X
24VAC Input
GND