Administrating the Camera
Setting the Alarm Out 1 or 2 — Alarm out 1 or 2 setting Page
33
Available period
Select the period for which the alarm mode is available.
Always: The alarm mode is available any time.
Use scheduler: The alarm mode is available according
to the schedule selected on the Schedule No. menu
below.
Schedule No.
When Use scheduler is selected on the Available period
menu, select the schedule you want the alarm mode
being available.
Click to select the check box(es) 1 to 6. You can select
multiple schedules.
To check the contents of schedules, click Schedule
check. (See “Setting the Schedule — Schedule setting
Page” on page 39.)
Periodical sending mode setting
Section
Interval time
Type the interval at which you want to send an E-mail
with a still image periodically. You can set the hour (H)
and minutes (M) between 30 minutes and 24 hours (one
day).
Available period
Select the period for which the periodical sending mode
is available.
Always: The periodical sending mode is available any
time.
Use scheduler: The periodical sending mode is
available according to the schedule selected on the
Schedule No. menu below.
Schedule No.
When Use scheduler is selected on the Available period
menu, select the schedule you want the perdiodical
sending mode being available.
Click to select the check box(es) 1 to 6. You can select
multiple schedules.
To check the contents of schedules, click Schedule
check. (See “Setting the Schedule — Schedule setting
Page” on page 39.)
Setting the Alarm Out 1
or 2
— Alarm out 1 or 2 setting Page
When you click Alarm out 1 on the Administrator
menu, the Alarm out 1 setting page appears. When you
click Alarm out 2 on the Administrator menu, the
Alarm out 2 setting page appears.
Use these pages to set up for the Alarm out function that
controls the alarm out 1 or alarm out 2 of the I/O port
located on the rear the camera. You can control the
alarm out when a trigger occurs by an external sensor
input, the built-in activity detection function, a manual
trigger button or the timer.
The setting items for alarm out 1 and alarm out 2 are the
same. This section explains how to set alarm out 1 as an
example.
Activating/Deactivating the Alarm
Out 1 Function
— Alarm out 1 usage setting Page
To activate the Alarm out 1 function, select Use alarm
out 1 function and click OK. The Alarm out 1 setting
page appears.
When you do not use the Alarm out 1 function, select Do
not use alarm out 1 function and click OK.
Setting the Alarm Out 1 Function
— Alarm out 1 setting Page
Mode
Select the mode of the Alarm out 1 function.
Manual: Controls the alarm out 1 manually.
In this mode, you can short-circuit and open the
alarm out 1 by clicking the (Trigger) button on
the main viewer page. (See “Controlling the
Application Manually” on page 12.)