Administrating the Camera
Setting the Alarm Out 1 or 2 — Alarm out 1 or 2 setting Page
34
Setting the Alarm Out 1
or 2
— Alarm out 1 or 2 setting Page
When you click Alarm out 1 on the Administrator
menu, the Alarm out 1 setting page appears. When you
click Alarm out 2 on the Administrator menu, the
Alarm out 2 setting page appears.
Use these pages to set up for the Alarm out function that
controls the alarm out 1 or alarm out 2 of the I/O port
located on the rear the camera. You can control the
alarm out when a trigger occurs by an external sensor
input, the built-in activity detection function, a manual
trigger button, the Day/Night function or the timer.
The setting items for alarm out 1 and alarm out 2 are the
same. This section explains how to set alarm out 1 as an
example.
Activating/Deactivating the Alarm
Out 1 Function
— Alarm out 1 usage setting Page
To activate the Alarm out 1 function, select Use alarm
out 1 function and click OK. The Alarm out 1 setting
page appears.
When you do not use the Alarm out 1 function, select Do
not use alarm out 1 function and click OK.
Setting the Alarm Out 1 Function
— Alarm out 1 setting Page
Mode
Select the mode of the Alarm out 1 function.
Manual: Controls the alarm out 1 manually.
In this mode, you can short-circuit and open the
alarm out 1 by clicking the (Trigger) button on
the main viewer page. (See “Controlling the
Application Manually” on page 13.)
Day/Night: Controls alarm out 1 by synchronizing with
the Day/Night function of the camera. When you
select Day/Night, the Day/Night setting button
appears. Click the button, and the Camera setting
page appears and you can set the Day/Night function
(see page 21).
In the Night mode, the relay corresponding to the
alarm out 1 is short-circuited. In the Day mode, it is
open.
Alarm: Controls alarm out 1 by synchronizing with an
external sensor input or the built-in activity detection
function. When you select Alarm, the Alarm mode
setting section appears (see page 34).
Timer: Controls alarm out 1 by the timer. When you
select Timer, the Timer mode setting section appears
(see page 35).
Alarm mode setting Section
Alarm
Select the alarm to link the alarm out 1 function. If the
selected alarm is detected, the alarm out 1 status
changes.
Sensor 1: External sensor connected to sensor input 1 of
the camera I/O port
Sensor 2: External sensor connected to sensor input 2 of
the camera I/O port
Sensor 3: External sensor connected to sensor input 3 of
the camera I/O port
Activity detection: The activity detection function built
in the camera.
To set the activity detection function, click Activity
detection. The Activity detection setting page
appears (see page 40).
Available period
Select the period for which the alarm mode is available.
Always: The alarm mode is available any time.
Use scheduler: The alarm mode is available according
to the schedule selected on the Schedule No. menu
below.
Schedule No.
When Use scheduler is selected on the Available period
menu, select the schedule you want the alarm mode
being available.
Click to select the check box(es) 1 to 6. You can select