Adjustment
Menu Operation
17
1 Display LIMITED CAL, by pressing the F or f
button.
2 Select ON by pressing the G or g button.
To reset to the default status
If you reset to the default status, the calibration is
not performed by selecting FULL RANGE CAL.
1 Display CAL RESET by pressing the F or f
button.
2 Press the EXEC button.
4
Press the MENU button.
The unit returns to standby status and READY is
displayed on the LCD.
Adjusting the Tone
You can adjust the high tone (dark areas of the images)
and the low one (light areas of images).
1
Press the MENU button.
2
Display the DENSITY ADJ menu by pressing the
F or f button, then press the g button.
The unit enters the automatic tone adjustment
mode.
3
Display PATTERN PRINT by pressing the F or f
button.
4
Press the EXEC button to make a printout of the
pattern print.
Display ON in capital letters by pressing the G or g
button.
3
5
1
24