Allied International V2.4.0 Digital Camera User Manual


 
Camera interfaces
OSCAR Technical Manual V2.4.0
44
Outputs
Output features are configured by software. Any signal can be placed on any
output.
The main features of output signals are described below:
Note
L
Switching trigger delay to ON also switches external
Trigger_Mode_0 to ON.
This feature works with external Trigger_Mode_0 only.
Note
L
For a general description of the outputs and warnings see
the Hardware Installation Guide, Chapter OSCAR output
description.
Signal Description
IntEna (Integration Enable) signal This signal displays the time in which exposure
was made. By using a register, this output can be
delayed by up to 1.05 seconds. This signal can be
used to fire a strobe flash.
Fval (Frame valid) signal This feature signals readout from the sensor. This
signal Fval follows IntEna.
Busy signal This signal appears when:
the exposure is being made or
the sensor is being read out or
data transmission is active.
The camera is busy.
Table 16: Output signals