Axis Communications Q1602 Security Camera User Manual


 
AXIS Q1602 N etwork Camera
Hardware Overview
Replacing the lens
It is possible to use optional lenses for the Axis product.
To replace the lens:
1. Disconnect the iris cable.
2. Unscrew the standard lens.
3. Attach and screw on the new lens.
Note
There is no need to restart the Axis product after changing the lens. However, the product must be restarted if you are
interchanging between a P-iris, DC-Iris or xed/manual iris lens. In order to set the focus and po sition the lens, the Axis
product must be connected to the network.
To change the iris conguration:
1. Go to Setup > Video and Audio > Cam era Settings. Iris conguration shows the current congured iris type.
2. Click Edit.
3. Select the installed iris lens from the drop-down list and click OK.
Note
For iris lenses not listed in the dro p-dow n list, d ownload the iris conguration l e from www.axis.com
To upload and use the downloaded conguration le, click the Uploa d tab. Click Browse and select the conguration
le. Click Upload. The installed iris lens should now be included in the Iris Selection drop-down list, select it and press
OK. If you select a DC iris conguration le for a P-iris le ns, an error message will appear below the iris conguration
type in the Camera Settings page.
7